OEC 9800

GE OEC 9800 Large C-Arm for Sale, Lease or Rent.

Product Information

The GE OEC 9800 Large C-Arm is a high-performance mobile C-arm that has set the standard for imaging quality, versatility, and reliability in surgical and clinical environments. With over 11,000 systems in use worldwide, the OEC 9800 is trusted by healthcare professionals for its ability to capture clear, high-resolution images in a wide range of procedures, including orthopedic, general surgery, pain management, spine, and vascular applications. Equipped with a powerful 15kW rotating anode X-ray tube and a small focal spot, the 9800 provides excellent penetration power for dense anatomy and long fluoroscopy times, making it a dependable solution for even the most complex cases.

The 9800 Plus features proprietary OEC technology, including Smart Metal and Smart Window, which automatically optimize image quality when metal objects are introduced into the X-ray field or when the collimator position changes. The Auto Trak feature detects and stabilizes the target anatomy during live fluoroscopy, minimizing dark images and burnout. With a versatile design, the OEC 9800 offers multiple configurations, including 9”, 12”, and Super C options, to accommodate various clinical needs. The Super C model, in particular, offers a 55-degree overscan for capturing steep angle images in challenging surgical environments.

For ease of use, the OEC 9800 is equipped with dual-side C-arm controls, intuitive software that requires just three clicks to obtain an image, and a compact frame that provides ample free space and C-arm depth for unobstructed patient access. The system’s dual 16-inch high-resolution monitors display sharp, detailed images for clear visualization during procedures. Its durable build and patented battery buffer technology ensure consistent performance and reduced downtime, making it a reliable choice for high-demand settings like ERs, ORs, ICUs, and outpatient clinics.

  • 60kHz high frequency
  • 15kWpower
  • Up to 120kVp
  • Up to 75mA for radiographic film exposure
  • Continuous high-level fluoro (HLF) up to 20mA
  • Digital spot up to 75mA
  • Digital cine pulse:
    • 15 pulses per second, 60 Hz
    • 12 pulses per second, 50 Hz
    • Up to 150mA
    • 10ms pulse width
  • Full power from standard wall outlet
  • Patented Battery buffered design
  • Rotating anode x-ray tube
  • 0.3 and 0.6 nominal focal spots
  • Anode heat capacity: 300,000 HU
  • Anode cooling rate: 85,000 HU/min
  • Housing heat capacity: 1,600,000 HU
  • 9″ (23cm) Standard C-Arm housing cooling rate 15,000 HU/min
  • 9″ (23cm) Super C-Arm and 12″ (31cm) Standard CArm housing cooling rate 22,500 HU/min
  • Digitally adjusts image display
  • Image update
    • Image rotation
    • Image reversal (side-to-side)
    • Image invert (top-to-bottom)
  • Image positioning without additional exposure
  • On-screen collimator position indication
  • PreView iris collimator
  • PreView Tungsten rotatable double leaf collimator
  • Adjusts collimators without x-ray exposure
  • kVp range: 40-120
  • mA range:
    • 0.2-10 normal mode and operator
    • 0.2-20 HLF (high level fluoro)
  • Auto and manual fluoro modes
  • AutoTrak ABS varies mA, kVp, camera gain
  • kVp range: 40-120
  • mA range: 0.2 -10
  • Pulse rate: 1, 2, 3, 8
  • Pulse width: 25 or 50 ms
  • AutoTrak ABS, mA, kVp, camera gain
  • Reduces x-ray dose to patient and operator
  • kVp range: 40-120
  • mA range: 0.2-40
  • Pulse rate: 1, 2, 4, 8
  • AutoTrak ABS, mA kVp, and camera gain
  • kVp range: 40-120
  • mA range: up to 150
  • Pulse rate: 15 pps (60 Hz), 12 pps (50Hz)
  • Pulse width: 10ms
  • AutoTrak ABS, mA, kVp, camera gain
  • kVp Range: 40-120
  • mA range: up to 75
  • Automatic exposure termination and automatic image save
  • mA range: up to 75
  • mAs range: up to 300
  • Computer controlled exposure time
  • Optional film cassette holder
    • 10×12″ for 9″ II
    • 14×14 for 12″ II

Includes all the GSP features and:

  • 200 or 400 image storage
  • Zoom and roam function
  • Image annotation
  • Measure software

Includes all the ESP features and:

  • Real-time digital subtraction (DSA)
  • Peak opacification
  • 8fps dynamic digital disk
    • Recording /playback rate: 1, 2, 4, 8fps
    • Recording time: 5 minutes @ 8fps

Includes all the ESP features and:

  • Real-time digital subtraction (DSA)
  • Road mapping
  • Peak opacification
  • Re-registration
  • Variable landmarking
  • Mask save/recall
  • Auto cine loop playback
  • Digital cine pulse mode:
    • 15 pulses/sec
    • Up to 150mA
    • 10ms pulse width
  • 15fps dynamic digital disk:
    • Recording/playback rate: 1, 2, 4, 8, 15fps
    • Recording time: 10 minutes @ 15fps (time depends on record frame rate)

Includes all the Vascular features and:

  • 30fps dynamic digital disk:
    • Recording/playback rate: 1, 2, 4, 8, 15, 30fps
    • Recording time: 10 minutes @ 30fps (time depends on record frame rate)

Includes all the Neuro-Vascular features and:

  • Single leaf curved collimator
  • Three pedal footswitch
  • Upgraded x-ray tube cooling
  • U.S. 21 CFR Subchapter K
  • NFPA 99
  • UL 60601-A (CSA/NRTL)
  • IEC60601-1 (plus relevant collateral and particular standards)
  • Tri-mode 9″/6″/4.5″ (23cm/15cm/11cm) image intensifier
  • Minimum central resolution (at the monitor):
    • 9″ (23cm): 2.1 lp/mm
    • 6″ (12cm): 2.9 lp/mm
    • 4.5″ (11cm): 3.4 lp/mm
  • DQE: 65% (typical)
  • Tri-mode 12″/9″/6″ (31cm/23cm/15cm) image intensifier
  • Minimum central resolution (at the monitor):
    • 12″ (31cm): 1.5 lp/mm
    • 9″ (23cm): 2.1 lp/mm
    • 6″ (12cm): 2.9 lp/mm
  • DQE: 65% (typical)
  • Automatically seeks the subject anatomy anywhere within the imaging field and selects the optimum imaging technique
  • Automatically adjust to anatomical size and location
  • Provides uniform image quality throughout entire image
  • Simplifies operation
  • Smart Window:
    • Dynamically senses the collimator position and automatically adjusts brightness and contrast to produce high image quality.
  • Smart Metal:
    • Allows user to adjust automatic brightness and contrast sensitivity levels to metal
    • Provides optimum image quality even when metal is introduced to the field
  • Tungsten Collimator:
    • Denser collimator limits x-ray exposure area
    • Reduces scatter radiation
    • Improves image detail
  • High resolution 1k x 1k CCD camera
  • Full frame capture
  • Motorized rotation
  • On-screen orientation indicator (real-time feedback without fluoro)
  • Left-right image reversal
  • Top-bottom image invert
  • Dual 16″ (41cm) square monitors
  • Anti-glare, progressive full frame scan monitor
  • Touch screen system control
  • 1,000 line high resolution monitors
  • Ambient room-light compensation
  • 32″ LED Lit LCD Display With Dual Screen Capabilities
  • Anti-glare, progressive full frame scan monitor
  • Touch screen system control
  • 2 Mega Pixel high-resolution output
  • Ambient room-light compensation
  • 1k x 1k x 16 bit image processing
  • Noise filter with on-screen indicator
  • Real-time variable edge enhancement
  • Automatic digital brightness and contrast control
  • Negate mode
  • Save and auto-save feature
  • Swap and auto-swap feature
  • Patient information
    • Examination list
    • Customized patient information
  • Customize functions:
    • Workstation set-up
    • Mainframe set-up
    • Patient information set-up
    • Date/time set-up
    • DICOM 3.0 interface set-up
  • Last image hold
  • 63 image storage
  • Integrated DICOM interface (store, print, worklist)
  • HIPAA SecureView:
    • Password protection
    • Blank screen function
    • Delete all
  • Adds Larger “C” for increased orbital rotation (145 degrees)
  • Increased Arc Depth (33″ / 838mm)
  • Adds motorized movements of c-arm
  • CD/DVD Writer digital interface (external)
  • Integrated DICOM 3.0 interface
  • Integrated film/paper printer
    • No film developing required
    • 8×10″ (20.3cm x 25.5 cm) laser quality film/paper
    • Multi-format, 1,2, 4 on 1
    • Multi-copy capability
  • Thermal printers
  • Entire system is computer controlled and software upgradeable
  • Touchscreen control simplifies operation
  • Automated system operation requires minimum operator interface
  • Multi-functional controls
    • Footswitch
    • IR remote (optional)
    • Hand-held control
  • Simplified keyboard
  • Multi-Purpose image directory
    • Retrieve and review images
    • Compose hardcopy films
    • Copy images
    • X-ray dose summary
  • Input power (69Hz ir 50Hz)
    • 100v @ 20 A (Japan)
    • 120V @ 12 A
    • 00V, 220V, 230V, 240V @ 10 A

Request A Quote